IDEM’s coded non-contact safety interlocks are designed to conform to IEC 60947-5-3 and be used as directed by ISO12100, ISO14121 and ISO14119. They feature solid state technology, providing a high tolerance to shock, vibration and tampering.
The hall effect operation means the contacts are volt free with a switching capability of 0.2A dc. They are suitable for hinged, sliding or removable guard applications and can connect to most safety relays to provide a higher level of functional safety.
Features:
• Housing/Fixing: Industry Standard, Wide body
• Material: High spec polyester, ideal for exposure to chemical cleaning agents
• Contacts: Up to 2 N/C safety outputs and 1 N/O auxiliary output.
• Sensing Distance: Wide 14mm operation
• Ingress Protection: IP67 and IP69K
• Operating Temperature: -25C to +80C
• Connection: Pre-Wired or M12 8-Pole Quick Connect
• Indication: Single Colour LED – Green when door closed
Important:
• LED is located on the top of the switch