Wind speed and direction display for outdoors with data recording. IP65.
WM44 V3 is a wind speed and direction display for outdoors with 2 alarm relays. Possibility of connecting wind sensors with a frequency, 4-20 mA analogue or RF output. Also wind direction sensors with 4-20mA analogue or RF output can be connected too. An anemometer and a wind vane or 2 anemometers can be connected at the same time. Last 96 hours graphic on screen and data recording in internal memory.
For outdoor/indoor installation (IP65)
Backlighted Graphic Liquid Crystal Display
Adjustable wind speed alarms
4-20mA analogue output
Last 96 hours graphic
uSD-based datalogger
Sensors
The following sensors can be connected:
• Anemometers: pulses output, 4-20mA or RF*.
• Wind vanes: 4-20mA or RF*
Anemometer and Wind vane can be connected and showed at the same time, also 2 anemometers but they must be 4-20mA or different types, 2-pulses output anemometers or 2-RF anemometers
Alarms
The alarm is triggered when the wind speed reaches or exceeds theprogrammed value. It includes a delay, configurable by keyboard, toprevent the alarm from being triggered by gusts of wind. The alarm is deactivated when the wind speed drops below the programmed value. It also has a configurable delay to prevent the alarm from being deactivated by temporary periods of low-intensity wind.
If ALARM2 is triggered, the reading will blink to warn about the danger. If the 2 alarms are reffered to the same anemometer, the activation of ALARM2 deactivates ALARM1.
Alarms configuration: Trigger values, polarity, intermittent or continuous alarm, alarm latching (only ALARM2) Alarms outputs