- Drinking water network diagnostic loggers
- Battery powered, 500 000 data memory
- 2x digital contact inputs or counter 100 Hz max (Ready for 4 digital inputs),
- 1x RS485 Modbus,
- 2x 4-20mA inputs
- 1x open collector output, 1x Modbus RS485
- Wireless configuration and data collection via radio. Available templates in Avelour software
- 2G/4G (LTE-M / NB-IoT) communication option to Ijitrack.com or your server (secure protocol or .CSV)
- IP68 housing : 2m / 100 days
- Excel report
This compact battery powered data logger allows you many water network applications (pulse count, Modbus flow meter, 4-20mA, external pressure sensor, …)
The BLUE range of data loggers for optimised management of drinking water network surveys, sectorisation.
- Flow logging : Connection to electromagnetic flowmeters via Modbus (Krohne, ABB, Siemens, …).
- Recording of volumes by pulse counting (100Hz max) : Use of a Cyble / pulse unit to be connected to the drinking water meter. Remote reading of water meters
- Default / door opening logging, connected to a digital input.
- Control and command of a control valve via digital output.
Quick radio configuration of the equipment
The logger can be configured on site by radio using a radio kit (radio transmitters and receivers to be connected via USB to a computer). The connection is direct, without the need to activate the device. This kit includes Avelour 7 software, which provides assisted application configuration models at each stage (measurement frequency, thresholds, conversions, data communication options and tests, …). Several applications can be configured for one logger.