Ideal for Platform Stabilization
The GI-CVG-N1100D is built with Coriolis technology to deliver true tactical grade performance in a small, lightweight package. With an improved Angular Random Walk and excellent short-term bias stability, the GI-CVG-N1100D is a perfect fit to for Land-Based Platforms:
Key Performance Features
•Small packaging
•Digital interface
•Outstanding Short-term Stability
•Excellent Angular Random Walk
•Very High MTBF
•Environmentally rugged
Specification
Parameters Unit Values
GI-CVG-N1100D
Number of axis One
Output format Digital
Output interface Asynchronous RS-422
Output signal rate Hz 7900
Temperature compensation (Bias, SF) Yes
Measurement range deg/sec ±160
Bandwidth (-3dB) Hz ≥ 300
In run Bias stability (room temp.) deg/hr ≤0.22
Bias stability, full temperature range, 1σ deg/hr ≤ 50 (Note #1)
Bias repeatability, turn-on to turn-on, 1σ deg/hr 1 typical
Angular Random Walk (steady conditions) deg/√hr 0.01 typical
Quiescent noise (1 – 100 Hz), RMS deg/sec ≤ 0.002
Scale factor error, full temperature range, 1σ ppm ≤ 3500
Scale factor linearity ppm ≤ 1500
Start up time sec 1 sec typical
Input signal (MIL STD 461 and 1275) VDC +12 VDC to +36 VDC
Power consumption Watt < 2.5 @15V
Operational temperature degC -40 to +85
Storage temperature degC -55 to +90