. The main structure has a vertical partition to separate the drive section (rear) from the operating zones (front).
. GMP-compliant cantilever (balcony type) layout for easy, pharmaceutically compliant cleaning.
. Adopts digital position indicator achieves straightforward adjustment.
. Equipped with format locking, positioning system, and quick-fitting, tool-free design, it achieves a highly straightforward format changeover (new).
In the sealing station, when the machine stops, the heating sealing mold can rise automatically to prevent hot air from getting into the blister pockets, preserving medicine effectiveness.
. Sealing pressure adopts the gas-hydraulic pressure cylinder, so the pressure can be set freely according to the sealing area (commonly, a larger sealing area requires higher pressure) (new).
. This machine has an integrated forming material splicer to enhance efficiency during material replacement.
The upper and lower plates adopt a contact heating method that significantly reduces the forming temperature. Thus, shrinkage, deformation of packaging material, and power consumption are minimized.
. A quick-fitting design enables the replacement of lidding material easily within 10 seconds.
The blister length can be set free through the touch-screen user Interface, which reduces the time for a format changeover.
The width of forming, sealing, and embossing stations reaches 180mm, which is suitable for mass production.