The pneumatic AS-Interface module AirBox 1 has 2 digital inputs and 2 pneumatical outputs. The input sockets can be wired up with sensors (PNP, via M12 plugs) in 2- or 3-wire connection. The sensors are supplied with energy from the pneumatic module. The outputs and the compressed air supply are connected to the module via a 8 mm plug-in tube connector. The recessed manual override can only be used with a tooling. Use outside diameter tubing only.
Product characteristics:
Air flow rate at 6/0 bar550 Nl/min
Air flow rate at 6/5 bar350 Nl/min
Ambient temperature0 °C
AS-i Certificate (No)44701
AS-i Specification2.0
Compressed air consistencyfiltered (5µm), oiled (ISO-VG10) or unoiled
Configuration I/O I/O, ID, ID1, ID2 (Hex)3, F, F, F
Digital Input / Pneumatic Output2 DI / 2 PO
Dimensions(l x b x h in mm) 80 x 45 x 48
Extended adressing mode possibleno
Housing materialPBT
Input circuitPNP (inputs)
Max. current for all inputs together200 mA
Max. current for all inputs together100 mA
Nominal voltage26,5 - 31,6 V
Operating voltage(Digital Inputs) 18 - 30 V
Particular CharacteristicsExhaust filter
Pneumatic connection8 mm tube coupling
Power supplyAS-i
Pressure range2 - 8 bar
ProtectionIP65 (with exhaust filter)
SealingNBR
Sensor supply100 mA
Short-circuit protectedyes
Valve function2 x 3/2-way [monostable]
Weightapproximately 200 g