nanoFlu fluorometers are low-priced, submersible miniaturized fluorometers for highly precise and selective measurement of CDOM (colored dissolved organic matter, yellow substances), chlorophyll a or phycocyanin in cyanobacteria. Long-term stability of measurements is ensured by the combination of low power consumption and innovative coating of the optical window, as an energy efficient and environmentally friendly anti-fouling solution. The devices can be used in diverse applications for the monitoring of sea and river waters, as well as in drinking- and wastewater treatment systems. Internal reference signals of the high performance LEDs used for fluorescence excitation compensate aging effects and temperature influences.
High sensitivity
Nano coating
Fast data acquisition
Electronic light compensation
Compact size
Low power consumption
Low costs
Measurement technology - -
light source: LED
detector: Photo diodes
Measurement principle - Fluorescence
Parameter -
CDOM [μg/L]
or chlorophyll a [μg/L]
or phycocyanin [μg/L]
or rhodamine [μg/L]
or fluorescein [μg/L]
Measuring range -
0...200 µg/L
0...200 ppb
Measurement accuracy - ±5 %
Turbidity compensation - No
Data logger - No
T100 response time - 6 s
Measurement interval - 3 s
Housing material - Stainless steel (1.4571/1.4404) or titanium (3.7035)
Dimensions (L x Ø) - 171 mm x 36 mm - ~ 6.1˝ x 1.4˝
Weight -
stainless steel: 0.5 kg
titanium: 0.4 kg
-
~ 1.1 lbs
~ 0.9 lbs
Interface -
digital: Ethernet (TCP/IP)
RS-232 or RS-485 (Modbus RTU)
Power consumption - typical < 1 W
Power supply - 12...24 VDC (± 10 %)