TDR-guided wave radar level transmitter NGR
for liquids4-20 mA2-wire

TDR-guided wave radar level transmitter
TDR-guided wave radar level transmitter
Add to favorites
Compare this product
 

Characteristics

Technology
TDR-guided wave radar
Medium
for liquids
Interface
4-20 mA, 2-wire, IO-Link
Applications
for storage tanks
Other characteristics
stainless steel, flexible, IP67
Level range

Max.: 4 m
(13'01" )

Min.: 0 m
(0'00" )

Process pressure

Max.: 10 bar
(145.04 psi)

Min.: -1 bar
(-14.5 psi)

Process temperature

Max.: 100 °C
(212 °F)

Min.: -20 °C
(-4 °F)

Description

The NGR is a level sensor that uses TDR technology (time domain reflectometry) and thus can be used in oil- and waterbased liquids without calibration. The NGR’s guided radar uses time-offlight technology to measure electromagnetic pulses. The time difference between the sent pulse and the reflected pulse is used to calculate the level, both as a continuous value (analogue output) and a freely positionable switching point (switching output). Due to its flexible probe that can be changed or cut, it is possible to integrate the sensor quickly into any application. The NGR can work in deposit-forming and foaming liquids. The sensor’s intuitive setup uses four buttons and a display to ensure quick and easy adaptation to the application. Connection: G ¾, ¾" NPT male thread Material connection: stainless steel, PTFE Accuracy: ±5 mm Power supply: 12 - 30 VDC, 2-wire Output: 4 - 20 mA, 0 - 10 V Switching output 1x PNP, 3x PNP / NPN
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.