FMCW radar level transmitter OPTIWAVE 3500 C
for liquidsHART4-20 mA

FMCW radar level transmitter - OPTIWAVE 3500 C - KROHNE Messtechnik GmbH - for liquids / HART / 4-20 mA
FMCW radar level transmitter - OPTIWAVE 3500 C - KROHNE Messtechnik GmbH - for liquids / HART / 4-20 mA
Add to favorites
Compare this product
 

Characteristics

Technology
FMCW radar
Medium
for liquids
Interface
HART, 4-20 mA, 2-wire
Applications
for small tanks
Other characteristics
ATEX, loop-powered, IP68, IP66
Level range

Max.: 50 m
(164'00" )

Min.: 0 m
(0'00" )

Process pressure

Max.: 25 bar
(362.59 psi)

Min.: -1 bar
(-14.5 psi)

Process temperature

Max.: 150 °C
(302 °F)

Min.: -40 °C
(-40 °F)

Description

Radar (FMCW) level transmitter for liquids with hygienic requirements • Continuous, non-contact level measurement in high and narrow, small and agitated tanks • 80 GHz radar, gasket-free Lens antenna • Measuring range: 0…50 m / 164 ft • -40…+150°C / +302°F; -1…25 barg / -14.5…362 psig The OPTIWAVE 3500 is a 2-wire 80 GHz radar (FMCW) level transmitter for liquids in hygienic applications. It is designed for continuous, non-contact level measurement in the food and beverage as well as pharmaceutical industry. The device features a flush-mounted PEEK Lens antenna with a small beam angle and dead zone for precise measurement even in small and narrow tanks with agitators. It is equally suited for use on larger tanks, measuring distances of up to 50 m / 164 ft. The OPTIWAVE 3500 fits applications with any finished or raw product – from raw milk, wine or juice to solvents. As the radar withstands process temperatures up to +150°C / +302°F and pressures up to 25 barg / 362 psig, it can be used in CIP/SIP cleaning procedures. The OPTIWAVE 3500 offers a large choice of hygienic process connections. It comes with extensive device diagnostics as well as HART®7 communication. Product highlights • 2-wire, loop-powered, with HART®7 • Small dead zone and beam angle (8° with DN40 / 1.5” antenna, 10° with DN25 / 1” antenna ) • ± 2 mm / 0.08” accuracy • Can measure in fast moving processes (≤60 m/min /| 196.85 ft/min) • Empty tank spectrum function eliminates false reflections caused by tank internals • Suitable for SIP (Sterilisation In Place) and CIP (Cleaning In Place) • Large choice of hygienic process connections

Catalogs

No catalogs are available for this product.

See all of KROHNE Messtechnik GmbH‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.