Lanemark KS burners provide the process heat for Ethylene Cracking Furnaces with side fired, horizontally mounted burners (Radiant Wall or Vertical Flat Flame type) combined with floor mounted, vertically up fired burners (Round or Flat Flame).
The burners’ stable, tightly controlled flame profile allows a wide range of typically high calorific value fuel gases such as natural gas and refinery fuel gas to be fired either on their own or in combination. Low NOx, CO and noise emissions together with high levels of turndown and flexibility ensure burner stability across the full operating range.
Burner models include configurations for the combustion air to be supplied to the burner in natural draft, induced draft or forced draft modes all at low excess air operation. In forced draft mode the combustion air can be ambient, preheated or may be supplied from a gas turbine exhaust. Burners can include manual ignition, with portable spark igniters or portable pilot as well as with fixed manual pilots, or can be supplied as fully automatic pilot burners.