Functions - Activation input
Type - 2, IEC/EN 61496, in combination with a suitable test monitoring unit, e.g. MSI-TR1B, In combination with a suitable test monitoring unit, e.g. MSI-TR1B
SIL - 1, IEC 61508, in combination with a suitable test monitoring unit, e.g. MSI-TR1B, In combination with a suitable test monitoring unit, e.g. MSI-TR1B
SILCL - 1, IEC/EN 62061, in combination with a suitable test monitoring unit, e.g. MSI-TR1B, In combination with a suitable test monitoring unit, e.g. MSI-TR1B
Performance Level (PL) - c, EN ISO 13849-1:2008, In combination with a suitable test monitoring unit, e.g. MSI-TR1B
MTTFd - 400 years, EN ISO 13849-1
PFHD - 3E-10 per hour
Mission time - 20 years, EN ISO 13849-1
Category - 2, EN ISO 13849, In combination with a suitable test monitoring unit, e.g. MSI-TR1B
Operating range - 5 ... 70 m
Operating range limit - 5 ... 80 m
Light source - LED, Red
Wavelength - 630 nm
Transmitted-signal shape - Pulsed
LED group - 1
Opening angle, max. - -5 ... 5 °
Protective circuit - Polarity reversal protection
Short circuit protected
Supply voltage UB - 24 V, DC, -20 ... 20 %, Incl. residual ripple
Residual ripple - 10 %, From UB
Open-circuit current - 0 ... 40 mA
Number of activation inputs - 1 Piece(s)
Voltage type - DC
Switching voltage - high: ≥8V
low: ≤ 1.5 V
Switching voltage high, min. - 8 V
Switching voltage low, max. - 1.5 V
Activation/disable delay - 1 ms
Input resistance - 10,000 Ω, -30 ... 30 %
Active switching state - High
Switching frequency - 250 Hz
Response time - 2.5 ms
Readiness delay - 300 ms
Number of connections - 1 Piece(s)
Function - Signal IN
Voltage supply