Application - Stationary access guarding
Stationary danger zone guarding
Functions - Changeover between configurations
Connection of up to 6 sensors
Deactivation of sensor groups
Start/restart interlock (RES), selectable
Synchronization of controllers
Restart - Automatic
Manual
SILCL - 2, IEC/EN 62061
Performance Level (PL) - d, EN ISO 13849-1
MTTFd - 38 years, EN ISO 13849-1
PFHD - 1.56E-08 per hour
Mission time - 20 years, EN ISO 13849-1
Category - 3, EN ISO 13849-1
Protective circuit - External power supply unit with integrated short circuit protection
Overcurrent through integrated resettable fuse (max. 5s at 8A)
Supply voltage UB - 20 ... 28 V, DC
Current consumption, max. - 1,000 mA, Without external load
Power consumption, max. - 5 W
Number of connections - 5 Piece(s)
Function - Voltage supply
Type of connection - Terminal
Type of terminal - Screw terminal
No. of pins - 3 -pin
Function - BUS OUT
Type of connection - Terminal
Function - Signal IN
Signal OUT
Type of connection - Terminal
Function - Configuration/parametering
Type of connection - USB
Function - Configuration/parametering
Type of connection - RJ45
Dimension (W x H x L) - 105 mm x 58 mm x 103 mm
Housing material - Plastic
Net weight - 170 g
Housing color - White
Type of fastening - DIN rail mounting
Snap-on mounting
Ambient temperature, operation - -30 ... 60 °C
Ambient temperature, storage - -40 ... 80 °C
Relative humidity (non-condensing) - 0 ... 95 %
Degree of protection - IP 20
Protection class - II
Certifications - TÜV Süd Italia
UL