Type of scanning system -
Special version - 2 independent switching outputs
Measurement value output
Black-white error - ± 50 mm (2 … 90 % diffuse reflection)
Operating range - 0.05 ... 2.5 m
Operating range limit, white 90% - 0.05 ... 3 m
Adjustment range - 150 ... 3,000 mm, At 90% diffuse reflection
Light source - LED, Infrared
Light spot size [at sensor distance] -
Measurement range - 50 ... 3,000 mm
Resolution - 1.0 mm with active average value filter
Accuracy - -100 ... 100 mm
Reproducibility (1 sigma) - -15 ... 15 mm, For measurement range 50 to 2500 mm, depending on diffuse reflectance and object distance, at 20°C after 20 min. warmup time, measurement object ≥ 50 x 50 mm², with average value filter 10 (factory settings)
Measurement value output - via IO-Link
Optical distance measurement principle - Time of flight
Protective circuit - Polarity reversal protection
Short circuit protected
Transient protection
Supply voltage UB - 18 ... 30 V, DC, Incl. residual ripple
Residual ripple - 0 ... 15 %, From UB
Open-circuit current - 0 ... 32 mA
Switching hysteresis - 30 mm, Adjustable
Switching hysteresis (reserve) - 30 mm, Adjustable
Number of digital switching outputs - 2 Piece(s)
Switching element - Transistor, Push-pull
Switching principle - IO-Link / light switching (PNP)/dark switching (NPN)
Switching element - Transistor, Push-pull
Switching principle - Light switching (PNP)/dark switching (NPN)
Switching frequency - 2 ... 30 Hz, depending on diffuse reflectance
Response time - 70 ms, depending on diffuse reflectance