Application - Mobile danger zone guarding
Mobile side guarding
Stationary access guarding
Stationary danger zone guarding
Functions - Dynamic contactor monitoring (EDM), selectable
Four-field mode
Start/restart interlock (RES), selectable
Type - 3, IEC/EN 61496
SIL - 2, IEC 61508
SILCL - 2, IEC/EN 62061
Performance Level (PL) - d, EN ISO 13849-1
PFHD - 9E-08 per hour
Mission time - 20 years, EN ISO 13849-1
Category - 3, EN ISO 13849
Resolution (adjustable) - 30/40/50/60/70/150 mm
Minimum adjustable range - 50 mm
Number of field pairs, switchable - 1
Number of quads, switchable - 1
Number of protective functions - 1 Piece(s)
Number of independent sensor configurations - 1
Diffuse reflection, min. - 1.8 %
Operating range - 0 ... 4.5 m
Number of field pairs - 1
Operating range - 0 ... 20 m
Object size - 150 mm x 150 mm
Diffuse reflection, min. - 10 %
Light source - Laser, Infrared
Wavelength - 905 nm
Laser class - 1, IEC/EN 60825-1:2014
Transmitted-signal shape - Pulsed
Repetition frequency - 90 kHz
Angular resolution - 0.1 °
Scanning angle - 270 °
Protective circuit - Overvoltage protection
Supply voltage UB - 24 V, DC, -30 ... 20 %
Current consumption (without load), max. - 700 mA, (use power supply unit with 3 A)
Power consumption, max. - 17 W, For 24 V, plus output load