Device type - Receiver
Contains - 2x BT-NC sliding block
Application - Hand protection
Smart Process Gating
Function package - Smart Process Gating
Functions - Configuration by means of wiring
Fixed blanking with 1-beam tolerance
Fixed blanking without tolerance
Integration of "contact-based safety circuit"
Integration of "electronic safety-related switching outputs"
MaxiScan
Muting-timeout extension
Qualified stop
Smart Process Gating
Start/restart interlock (RES)
Transmission channel changeover
Type - 4, IEC/EN 61496
SIL - 3, IEC 61508
SILCL - 3, IEC/EN 62061
Performance Level (PL) - e, EN ISO 13849-1
PFHD - 7.73E-09 per hour
Mission time - 20 years, EN ISO 13849-1
Category - 4, EN ISO 13849
Total protective field height - 900 mm
Resolution 1 - 14 mm
Protective field height 1 - 300 mm
Resolution 2 - 30 mm
Protective field height 2 - 600 mm
Synchronization - Optical between transmitter and receiver
Protective circuit - Overvoltage protection
Short circuit protected
Supply voltage UB - 24 V, DC, -20 ... 20 %
Current consumption, max. - 150 mA
Fuse - 2 A semi time-lag
Number of digital switching inputs - 3 Piece(s)
Type - Digital switching input
Switching voltage high, min. - 18 V
Switching voltage low, max. - 2.5 V
Switching voltage, type. - 22.5 V
Voltage type - DC