• Unbalanced.
• System attached to the shaft by allen
screws.
• Not dependent on the rotation direction.
(*) The temperature resistance depends on the material of the
secondary seals used.
The operating limits are defined by the PV factor which is
determined for the sealing system characteristics and those of
the application.
DESCRIPTION:
Recommended for working with sticky fluids and
fluids laden with particles and fibres. Unlike the
multispring models, the wave spring model cannot
be blocked or obstructed and its open leaf design
produces a self-cleaning effect.
Standard L9 type stationary part.
Seal compliant with standard EN 12756 (KU).
Available with a pumping ring on the casing to re-
duce the temperature between the contact surfaces
and facilitate the barrier fluid movement in the case
of double mounting (reference LWS10-F).
Contact surface kits supplied available.