Our standard product range includes a selection of flexible heating jackets for pressurised gas cylinders. These have been designed with a variety of control options for both safe and hazardous “Ex” areas where there is risk of explosion. We manufacture to CE, ATEX/IECEx, UL and CSA standards in our ISO9001 certified factories in the UK.
As well as standard flexible heating jackets (detailed below) for the popular “K” sized cylinders, we can also design jackets for most cylinder sizes in both safe and hazardous areas, right up to several thousand litre capacity horizontal cylinders. These can be fitted with a variety of power and temperature control options, including our latest ATEX/IECEx patented “ProxATEX” digital controller, offering precise temperature measurement, multiple heating program adjustment options and user access control using secure NFC cards.
We can design jackets for most cylinder sizes, with our standard “HHG” being a popular size normally available for immediate delivery.
Product Specification: “K” size gas cylinder (others available to order)
Adjustable length: 680-830mm | Overall Height: 1050mm | Power supply: 110v or 230v(50/60Hz ac)
HHG (safe area): 450W with 0-90°C adjustable thermostat (-5 to 40°C range & digital options also available)
IHF/G/T4 (hazardous area): 100W, self-limiting to 30°C above ambient -II 2 G D Ex e IIC T4 Gb Ex tb IIIC T135°C Db
IHF-R/G/T4 (hazardous area): 100W, 0-50°C temperature regulator IHF-R/G/T3 (hazardous area): 285W, 0-85°C temperature regulator -II 2 G D Ex e IIC T4 Gb Ex tb IIIC T135°C Db
IHF-R/G/T3 (hazardous area): 285W, 0-85°C temperature regulator - II 2 G D Ex e IIC T3 Gb Ex tb IIIC T200°C Db