• Industrial case with DIN rail mounting suitable for Safe AREA installation
• Equipped with high efficiency redundant green and red LEDs for connection monitoring
• N.1 x N.O. contact for safety application up to SIL 2 (ECS-RF-DIN only)
• N.1 x SPST N.O. contact for clamp state remote monitoring
• N.2 x Ex i outputs for remote clamp on-board LEDs driving
Meets the requirements of ATEX Directive 2014/34/UE and related harmonized standards for Safe Area installation in connection with ECS’s clamps installed in ATEX Zone 1/21.
ATEX Marking
II (1)G [Ex ia Ga] IIC -20 °C ≤ Tamb ≤ +70 °C for gases, vapors and mists
II (1)D [Ex ia Da] IIIC -20 °C ≤ Tamb ≤ +70 °C for dusts
Clamp input Ex i
Uo=7.2 V, Io=345 mA, Po=621 mW, Co(IIC)=13,5 μF, Lo(IIC)=149 μH
LEDs outputs Ex i
Uo=7.2 V, Io=23 mA, Po=42 mW, Co(IIC)=13,5 μF, Lo(IIC)=34 mH
Monitoring contact
1x SPDT max 230Vac/1A 24Vdc/1A (resistive/inductive load)
Interlock contact
1x N.O. max 230Vac/1A 24Vdc/1A (resistive/inductive load) up to SIL2 acc. IEC 61508 (ECS-RF-DIN only)
Power supply
230 Vac + 5%
Max current
150 mA
Resistance threshold
10 Ω
Dimensions
162 x 90 x 63 mm (W x H x D)