Thermal conductivity measuring instrument TLOGWLS
laboratoryfor buildingwireless

Thermal conductivity measuring instrument - TLOGWLS - M.A.E. S.r.l. - laboratory / for building / wireless
Thermal conductivity measuring instrument - TLOGWLS - M.A.E. S.r.l. - laboratory / for building / wireless
Thermal conductivity measuring instrument - TLOGWLS - M.A.E. S.r.l. - laboratory / for building / wireless - image - 2
Thermal conductivity measuring instrument - TLOGWLS - M.A.E. S.r.l. - laboratory / for building / wireless - image - 3
Thermal conductivity measuring instrument - TLOGWLS - M.A.E. S.r.l. - laboratory / for building / wireless - image - 4
Thermal conductivity measuring instrument - TLOGWLS - M.A.E. S.r.l. - laboratory / for building / wireless - image - 5
Add to favorites
Compare this product
 

Characteristics

Measured value
thermal conductivity
Applications
laboratory, for building
Other characteristics
wireless

Description

TLOGWLS heat flux meter for transmittance measurements is characterized by the maximum accuracy in the data acquisition (24 bit resolution) as well as its great versatility and simple operation. Thanks to the use of four probes (for the measure of the contact temperature) and one heat flux plate connected to the main TLOGWLS unit through proper wireless connection (made up of some completely independent and proper remote units for the acquisition and transmission of data), instrument takes the measurement of transmittance values on opaque walls of whole buildings, as specifically required by the most recent normative regarding energy-saving. Recording modalities can be set by using the software in a very intuitive and quick way, in order to carry out monitoring with maximum accuracy and easiness. TLOGWLS heat flux meter is also arranged for medium and long-term acquisitions and it is suitable for the measure of environmental parameters both on site and in laboratory. Unit can also manage up to two optional couples of remote transmitting units TLW2; TLW3 in order to perform recording of the transmittance parameters in 3 different measurement areas in the same building at same time. All data acquired are downloaded on PC and processed by GTLAB software (provided with the equipment) for the direct calculation (through progressive average method) of K coefficient (transmittance) and parameters related to the thermal insulation of tested building. Instrument complies with ISO 9869 standard

Catalogs

No catalogs are available for this product.

See all of M.A.E. S.r.l.‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.