NG 100 and 160
without liquid filling
Service intended:
Suitable for gaseous and liquid, non-crystallizing media that will not obstruct the pressure system.
Scale range must be selected in consideration of the highest static pressure applied.
Fields of application:
● pneumatics, hydraulics
● heating and air conditioning technology
● Filter measurements
Construction:similary EN 837-1
Case:Ø 100 and 160 mm stainless steel
Protection class:IP 54 per EN 60529 / IEC 529
Pressure connection:2 x G1/2B, parallel behind, stainless steel 361L identified + and -
Pressure element:Diaphragm element stainless steel 316L, Diaphragm FPM/PA, Pressure chambers, 316Ti, with exhaust
Movement:stainless steel
Pointer:aluminium, black
Dial:Aluminium white, scale and lettering black
Window:Laminated safety glass
Accuracy class:class 1,6 / 2,5