for oxygen, security S2
● Service intended: Suitable for all gaseous and liquid media that will not obstruct the pressure system
to which copper alloys are resistant
Fields of application:
● for measuring oxygen, acetylene or argon
● welding technology
Construction:EN 837-1
Case:NG 50 and 63 steel, varnished
Protection class:IP 54 per EN 60529 / IEC 529
Pressure connection:NG63: G1/4 B, brass
Pressure element:Cu-alloy, 40 bar, helical type
Pointer:Aluminium or plastic, black
Dial:Aluminium white or plastic white Graduation and lettering black
Window:Instrument acrylic glass
Accuracy class:class 1,6 and 2,5
Temperature error, Tref 20°C:
rising temperature: +0,3 % of FS/ 10 K Falling temperature: -0,3 % of FS/ 10 K
Working pressure:
Steady : 0,75 x full scale value Fluctuating : 0,70 x full scale value Short time : 1,00 x full scale value