Characteristics

Type
climatic
Controlled parameter
humidity, temperature
Test type
stability
Capacity

749 l
(198 gal)

Temperature

Min.: -10 °C
(14 °F)

Max.: 60 °C
(140 °F)

Length

1,200 mm
(47.24 in)

Width

1,040 mm
(40.9 in)

Depth

600 mm
(24 in)

Description

Climate chamber ICH750 Unparalleled homogeneity of temperature and humidity! For stability testing according to ICH - WHO - EMA - ASEAN - GMP - GLP – GCCP. Temperature Setting temperature range: -10 to +60 °C Working temperature range: from -10°C up to +60°C without humidity (not suitable for long-term storing at sub-zero temperatures. During permanent operation, the glass door may ice over) Working temperature range: from +10°C up to +60°C with humidity and/or light Setting accuracy temperature: 0.1 °C Temperature sensor: 2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error Humidity Humidity: humidity supply with distilled water from external tank by self-priming pump Humidification: humidification by hot steam generator Humidity: active humidifying and de-humidifying adjustable from 10-80 % rh with digital display of relative humidity - resolution of display 0.1 %, setting accuracy 0.5 % Control technology ControlCOCKPIT: TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays. adjustable parameters: temperature (Celsius or Fahrenheit), fan speed, relative humidity, programme time, time zones, summertime/wintertime Language setting: German, English, Spanish, French, Polish, Czech, Hungarian Timer: Digital backwards counter with target time setting, adjustable from 1 minute to 99 days Function SetpointWAIT: the process time does not start until the set temperature is reached Calibration: three freely selectable values each, temperature/humidity, for two freely selectable values CO2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.