video corpo

Laboratory sterilizer SF160plus
hot airmedical

Laboratory sterilizer - SF160plus - Memmert GmbH + Co. KG - hot air / medical
Laboratory sterilizer - SF160plus - Memmert GmbH + Co. KG - hot air / medical
Laboratory sterilizer - SF160plus - Memmert GmbH + Co. KG - hot air / medical - image - 2
Add to favorites
Compare this product
 

Characteristics

Laboratory/process
laboratory
Sterilization method
hot air
Applications
medical
Temperature range

Max.: 250 °C
(482 °F)

Min.: 20 °C
(68 °F)

Capacity

161 l
(42.53 gal)

Weight

96 kg
(211.6 lb)

Width

560 mm
(22.05 in)

Height

720 mm
(28.35 in)

Depth

400 mm
(15.75 in)

Description

Steriliser SF160plus Safer than disinfection, hot-air sterilisation of containers and instruments Standard delivery Steriliser The indispensable safety feature for this hot air steriliser: Setpoint Wait. This means that the programme for sterilisation only starts when the set temperature has been reached. This feature can also be used with freely positionable Pt100 temperature sensors. Here the sterilisation time only begins when the set temperature has been reached at all measurement points, and reliable sterilisation is guaranteed at all times. Control technology ControlCOCKPIT: TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays. Language setting: German, English, Spanish, French, Polish, Czech, Hungarian Timer: Digital backwards counter with target time setting, adjustable from 1 minute to 99 days Function HeatBALANCE: adapting the distribution of the heating performance of the upper and lower heating circuit from -50 % to +50 % Function SetpointWAIT: the process time does not start until the set temperature is reached Calibration: three freely selectable temperature values adjustable parameters: temperature (Celsius or Fahrenheit), fan speed, air flap position, programme time, time zones, summertime/wintertime Ventilation Fan: forced air circulation by quite air turbine, adjustable in 10 % steps for each segment individually Fresh air: Admixture of pre-heated fresh air by electronically adjustable air flap Vent: vent connection with restrictor flap Communication Documentation: programme stored in case of power failure

Catalogs

No catalogs are available for this product.

See all of Memmert GmbH + Co. KG‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.