DC load bank NATURALLY COOLED series

DC load bank - NATURALLY COOLED series - METAL DEPLOYE RESISTOR
DC load bank - NATURALLY COOLED series - METAL DEPLOYE RESISTOR
DC load bank - NATURALLY COOLED series - METAL DEPLOYE RESISTOR - image - 2
DC load bank - NATURALLY COOLED series - METAL DEPLOYE RESISTOR - image - 3
DC load bank - NATURALLY COOLED series - METAL DEPLOYE RESISTOR - image - 4
DC load bank - NATURALLY COOLED series - METAL DEPLOYE RESISTOR - image - 5
DC load bank - NATURALLY COOLED series - METAL DEPLOYE RESISTOR - image - 6
Add to favorites
Compare this product
 

Characteristics

Options
DC

Description

The power resistors are utilized as a part of generator burden banks to abstain from fouling of the diesel motor when the generator is working at low power. Thusly, load bank are likewise used to decrease « wet stacking » issue in diesel motors. Furthermore, it is standard practice to utilize power resistors as burden banks to keep up batteries in electrical research facilities, mechanical testing offices and information transfers offices. PRINCIPLE Power resistors are used in generator load banks to avoid fouling of the diesel engine when the generator is operating at low power. Therefore, load bank are also used to reduce « wet stacking » issue in diesel engines. In addition, it is standard practice to use power resistors as load banks to maintain batteries in electrical laboratories, industrial testing facilities and telecommunications facilities. We offer inductive load banks that can vary their power factor between 0.8 and 1. Remote control or local, available in fixed and portable applications on any load banks. MARKETS Oil & Gas Utility Industry Energy Nuclear Data Center Renewable energy STANDAR RANGE : NATURALLY COOLED SERIES 400, 700, 800 FORCED COOLED SERIES (horizontal ventilation) RADIATOR MOUNTED LOAD BANK (Tunnel) CUSTOM MADE LOAD BANKS : Our modern techniques and tools (CAS, finites elements analysis, internal test facility for heating and vibration) enable us to design customised equipment : - Load banks to meet any power requirement - High voltage - Vertical forced cooling, - Centrifugal fan - Additional reactive loads - Tunnel resistor for use in the air duct of electrical generators - Control cabinet, automatic load shedding
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.