Power source - 1Phase, 220 - 240, 50Hz
Nominal cooling capacity (Min~Max) - kW - 5.0 ( 1.3 ~ 5.3 )
Nominal heating capacity (Min~Max) - kW - 5.8 ( 1.3 ~ 6.3 )
Power consumption - Cooling/Heating - kW - 1.59 / 1.62
EER/COP - Cooling/Heating - - 3.14 / 3.58
Max. running current - A - 14.5
Sound power
level - Indoor - Cooling/Heating - dB(A) - 60 / 60
Outdoor - Cooling/Heating - 64 / 65
Sound pressure
level - Indoor - Cooling (Hi/Me/Lo/Ulo) - 47 / 40 / 32 / 25
Heating (Hi/Me/Lo/Ulo) - 47 / 40 / 33 / 25
Outdoor - Cooling/Heating - 52 / 53
Air flow - Indoor - Cooling (Hi/Me/Lo/Ulo) - m3/min - 12.5 / 10.4 / 7.2 / 5.4
Heating (Hi/Me/Lo/Ulo) - 12.6 / 11.5 / 8.9 / 6.4
Outdoor - Cooling/Heating - 35.6 / 33.8
Exterior Dimensions - Indoor - Height x Width x Depth - mm - 294 x 798 x 210
Outdoor - 595 x 780(+62) x 290
Net weight - Indoor / Outdoor - kg - 9.5 / 33.0
Refrigerant - Type/GWP - - R32 / 675
Refrigerant - Charge - kg/TCO2Eq - 0.9 / 0.61
Refrigerant piping size - Liquid/Gas - ø inch - 6.35(1/4") / 12.7(1/2”)
Refrigerant line (one way) length - m - Max.25
Vertical height differences - Outdoor is higher/lower - m - Max.20 / Max.20
Outdoor operating
temperature range - Cooling - °C - -15~46
Heating - -20~24
Clean filter - - Allergen Clear Filter x 1, Photocatalytic Washable Deodorizing Filter x 1
Energy Class (Cooling/Heating) - - A++/A++
SEER - - 6.50
SCOP (Average climate) - - 4.30
Pdesign (cooling/heating(@-10°C)) - kW - 5.00/4.00
Annual Electricity Consumption (cooling/heating) - kWh/a - 270/1302
Designated Heating Season - - Average