Powered by MVD Technology, DIN rail-mounted transmitters easily fit into control room panels. A simple four-wire connection to the sensors for power and signal eliminates the expense of custom cabling
Features
Cut wiring expenses with a remote-mount transmitter using 35 mm DIN rail
Easily fit in control rooms – just a 0.03ft³ space requirement versus 1.0ft³ typically required for Coriolis transmitters
Simplify configuration with a four-wire connection to the sensors for power and signal
Diagnose for performance under entrained gas and batching from empty applications with MVD digital processing
Gain real-time and in-process measurement integrity assurance with Smart Meter Verification
Specifications
Output variables
•Mass & volume flow
•Net product content / flow
•Temperature
•Density
•Concentration
Local display
None
Power
•Minimum 19.2 to 28.8 VDC
•6.3 watts
•Meets Installation (Overvoltage) Category II, Pollution Degree 2 requirements
Input/output signals
•One active 4–20 mA output
•One active frequencty output
HART
Bell 202 signal is superimposed on the primary milliamp output