- Vertical level indicators with external aluminium guard, standard center-to-center distance 300-400-500 mm; consult our commercial/technical office for custom length.
- Polyamide PA 66 black end caps, transparent Polycarbonate tube; behind the tube is a graduated contrast screen for a visual check of the fluid level.
- Aluminium guard can be turned 90 degrees where necessary for side viewing.
- Zinc plated M12 bolts and nuts (available on request in Stainless steel AISI 303), Buna seals 70 durometer; Max tighnening torque suggested = 5 Nm (3.7 ft lbs).
- Suggested for applications with mineral oils, hydraulic fluids, diesel and fluid containing glycol. Avoid contact with gasoline, hydrocarbons and solvents (contact our technical office for compatibility with other chemical agents).
- The mounting can be made externally by providing 2 threaded holes M12 on the center-to-center distance, (tolerance ±0,5 mm) or they can be secured internally through 2 plain holes 12,2 MM (±0,2), using the flanged nuts.
- Max working temperature 80°C/176 F, max pressure suggested 1 bar/14,5 PSI (for use on pressure tanks contact our technical office).
- REED Switch Sensor is attached to the internal transparent tube, adjustable in height according to the control requirements of the level; minimum quote positioned at about 50 mm from the center of the lower bolt. The sensor is supplied with power cable (lenght 30 cm/0,98 ft) and M8 male connector; on request it is possible to provide a separate connection cable (length 250 mm/8.2 ft) complete with female M8 connector. Possibility to also apply more than of level sensors positioned at different heights.