Our cupellation furnace range is available in a range of sizes, suitable for a range of cupels. Our engineers work closely with our customers to select the right furnace for their needs. Key Benefits
Uses a No. 5 Muffle.
Takes 100 x 6a, 7a, 7as or 72 x 8s Cupels at one time.
Easy to maintain and operate.
Built to Industry Standards.
Technical Specifications
Construction
Cabinet is 5 mm steel sheet, mounted on a stand fabricated from 64 x 64 x 2.6mm R.H.S. and finished in Hammerfin blue enamel.
Refractory Lining
Hot face of 70% alumina fire-brick backed with insulating fire-brick.
Flame Supervision
LPG – Landis & Gyr LME 44 flame controller and U.V. cell
Nat. Gas & Distillate – Landis & Gyr LFL1.635.
Temperature Control
Electronic, Automatic control 1200°C, type “K” Thermocouple.
Internal Dimensions
300mm high x 480mm wide x 560mm deep.
Burner Equipment and Ratings
LPG – 1 x 40mm long pattern inspirator with flame retention nozzle. 270 mj/hr @ 140 kpa.
Natural Gas – Furnace Industries NG2 Burner package. 270mj/hr @ 3 kpa.
Distillate – Furnace Industries Oil Burner Package. 270mj/hr.
Electrical Requirements
The furnace is fitted with a 10 AMP single phase cord and plug top. Electrical load: 5 Amps.
Door Operation
Pneumatic rising. Operated by foot control.