Compact analyzer TMA 402 F3 Hyperion®
TMA

Compact analyzer - TMA 402 F3 Hyperion® - NETZSCH Analyzing & Testing - TMA
Compact analyzer - TMA 402 F3 Hyperion® - NETZSCH Analyzing & Testing - TMA
Compact analyzer - TMA 402 F3 Hyperion® - NETZSCH Analyzing & Testing - TMA - image - 2
Compact analyzer - TMA 402 F3 Hyperion® - NETZSCH Analyzing & Testing - TMA - image - 3
Compact analyzer - TMA 402 F3 Hyperion® - NETZSCH Analyzing & Testing - TMA - image - 4
Add to favorites
Compare this product
 

Characteristics

Configuration
compact
Technology
TMA

Description

TMA Analysis for Polymers Polymers undergo changes in their thermomechanical properties during heating and cooling. TMA analyses can give insights into molecular orientation and quenching effects during cooling. It allows the design of adhesives and other hybrid joints and quality control of shrink films. TMA analyses can hereby provide valuable insight into the composition, structure, production conditions or application possibilities for various materials. Determination of Viscoelastic Properties like Relaxation, Creep and Stress/Strain The TMA 402 F3 Hyperion® Polymer Edition now offers not only to keep the force constant and to measure the length change, but also to change the displacement and measure the corresponding force. This is for example used in a stress relaxation test. Here, a sample is stretched by a specific amount at a defined temperature. During the test, the deformation is kept constant and the progression of the force is recorded. This force continuously decreases as a result of material relaxation. Stress-relaxation is ultimately defined by the residual stress measured after a defined exposure period. The data can be depicted graphically in a stress-time diagram. It is then possible to read off both the stress-relaxation behavior and the values for the relaxation rate and time. Mechanical Cooling to -70°C The TMA 402 F3 Hyperion® Polymer Edition is specifically designed for polymer applications. It comes with a compact, highly reactive furnace capable of covering a temperature range from -70°C to 450°C using a mechanical cooling system without the need for LN₂.

Catalogs

No catalogs are available for this product.

See all of NETZSCH Analyzing & Testing‘s catalogs

Exhibitions

Meet this supplier at the following exhibition(s):

K-Messe	2025
K-Messe 2025

8-15 Oct 2025 Düsseldorf (Germany)

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.