Probe head-mounted temperature transmitter TxIsoBlock-HRT
type S thermocoupletype K thermocouplePt100

Probe head-mounted temperature transmitter - TxIsoBlock-HRT - Novus Automation - type S thermocouple / type K thermocouple / Pt100
Probe head-mounted temperature transmitter - TxIsoBlock-HRT - Novus Automation - type S thermocouple / type K thermocouple / Pt100
Add to favorites
Compare this product

Characteristics

Mounting
probe head-mounted
Input type
Pt100, Pt1000, type K thermocouple, type J thermocouple, type S thermocouple, type E thermocouple, type T thermocouple
Output signal
HART, 4-20 mA
Other characteristics
differential

Description

Temperature transmitter TxIsoBlock-HRT combines the proven quality of HART® certification with the robustness of NOVUS devices. The transmitter is compatible with HART® certified devices and it has electrical isolation between input and output, supporting voltage surges up to 1.5 kVrms. Its great differential is the total configuration through the two 4-20 mA current loop wires, which means more features for device configuration and monitoring. By using a worldwide known protocol with more than 40 million field instruments supporting HART® technology, NOVUS's temperature transmitter TxIsoBlock-HRT enables the use of standard HART® configuration and supervision software that provides flexibility to users. - Accuracy Typical: T/C: 0.07 % span ±1 °C (1.8 °F) NTC: 0.2 °C (0.36 °F) - Maximum: Pt1000 / mV: 0.15 % span Pt100: 0.15 % span T/C: 0.15 % span ±1 °C (1.8 °F) NTC: 0.45 °C (0.81 °F)" - Output Type: 4-20 mA - Output Resolution: 0.25 µA - Thermal Drift: < 0.05 % / 25 °C (77 °F) - Isolation Input-Output: 1.5 kVrms - Electric Protection: Reverse Polarity - HART® Version: HART V7, compatible with HART V5 - Configuration Interface: Through TxConfig-HRT adapter or HART® certified HandHeld - Configuration Software: TxConfig II - Approvals / Regulations: CE, NAMUR NE43, RoHS, Reach, HART® - Electromagnetic Compatibility CISPR 11 EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6 EN 61000-4-8 - Operating Conditions: -40 to 85 °C (-40 to 185 °F) | 0 to 90% RH - Power Supply: 4-20 mA Loop Powered (8.5 - 36 Vdc)

Catalogs

Exhibitions

Meet this supplier at the following exhibition(s):

HANNOVER 2025
HANNOVER 2025

31 Mar - 04 Apr 2025 Hannover (Germany) Hall 9 - Stand E60

  • More information

    Other Novus Automation products

    Sensing, Conditioning & Transmitters

    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.