Air sanitization device that allows the removal of the microbial load present in the environment.
It can be used full time and in the presence of the operators without side effects, as it does not have external UV-C rays emissions.
The air sucked in from the back passes first through a filter and then conveyed inside and irradiated with UV-C rays which have the wavelength necessary for the destruction of the DNA of bacteria, microorganisms and viruses, neutralizing their proliferation, such as proven by laboratory tests.
The 24 W PHILIPS UV-C lamp used is “ozone free” in order not to produce ozone, thus eliminating the risks for those exposed.
The device is built in stainless steel and local control.
With very low maintenance costs, it helps prevent operator infection, reduces the risk of surface contamination and avoids the use of chemical sprays in the air.
Technical features :
Power supply 220 V. 50 Hz
Absorbed Power: 40 W
UV-C lamps: 1 × 24 W
Lamp life: 9000 hours
Wavelength: 253.7 Nm
Air flow: 120 m3 / h
Operation: Continuous
External emission of UV-C rays None
Hazard: None
Ozone emission: None
Size: 20 x 20 x 60 cm.
Weight: 7 kg
UVC irradiation: 90 uW / cmq