Compact (104.5 mm), lightweight (1.3 kg) and easy-to-install Safety Laser Scanner
Operating state can be determined at a glance
Eight sector indicators* show the direction of intrusion.
Front display shows operating state and error codes.
Industry's first Ethernet-compliant Safety Laser Scanner allows the user to check operating state and analyze the cause of an emergency stop via LAN even in large-scale applications using multiple scanners.
For complex AGV applications, up to 70 combinations - each with one safety zone and two warning zones - can be set. The two warning zones can be set to support various purposes such as warning sound and speed control.
OMRON STI's innovative I/O method requires fewer inputs when configuring multiple zones. Only 4 inputs are required to select from 6 zone sets.
If all 8 inputs are used, up to 70 zone sets are available.
PTM (Pollution Tolerance Mode) enables a filter that allows the OS32C to distinguish between more than one detected reflection pulses. Ignoring small reflection pulses which could be caused by airborne dust or other contaminants in the safety zone.