The Pacific Power Source EMC Compliance Test Systems use a sophisticated Harmonics and Flicker measurement system and newly designed flicker impedance options to support single and three phase IEC 61000-3-XX AC – Power Line Harmonics and Flicker as well as IEC 61000-4-XX AC – Power Line immunity compliance testing of EUTs up to the maximum required current of 75A per phase.
This series consists of several system configurations to accommodate both single and three phase compliance testing at a wide range of power levels from 750VA to 100kVA. for EUT’s than can put power back on the AC utility grid, the AZX Series based ECTS2-Z models are recommended.
All ECTS2 systems use the same IEC 61000-3-XX Power Line Harmonics and Flicker Emissions and IEC 61000-4-XX Power Line Immunity test software.
The ECTS2 Series of EMC Compliance Test System allows EMC labs to perform full compliance testing of products to the following IEC standards:
Emissions:
IEC 61000-3-2 Harmonics and Inter Harmonics to 16A/phase
IEC 61000-3-12 Harmonics and Inter Harmonics to 75A/phase
IEC 61000-3-3 Flicker to 16A/phase
IEC 61000-3-11 Flicker to 75A/phase
Immunity
IEC 61000-4-11 AC Voltage Dips, Interruptions and Variations to 16A/phase
IEC 61000-4-13 Interharmonics
IEC 61000-4-14 AC Voltage Fluctuations
IEC 61000-4-17 DC Ripple
IEC 61000-4-27 AC Voltage Unbalance three phase
IEC 61000-4-28 Frequency Variations
IEC 61000-4-29 DC Voltage Dips, Interruptions and Variations (Pre-compliance)
IEC 61000-4-34 AC Voltage Dips, Interruptions and Variations to 75A/phase