Gas analyzer Aurora 19
processmoistureportable

Gas analyzer - Aurora 19 - Panametrics, a Baker Hughes business - process / moisture / portable
Gas analyzer - Aurora 19 - Panametrics, a Baker Hughes business - process / moisture / portable
Gas analyzer - Aurora 19 - Panametrics, a Baker Hughes business - process / moisture / portable - image - 2
Add to favorites
Compare this product
 

Characteristics

Measured entity
gas
Application domain
process
Measured value
moisture
Configuration
portable
Technology
TDLAS

Description

Panametrics Aurora 19 analyzer uses tunable diode laser absorption spectroscopy (TDLAS) to accurately measure moisture in a variety of background gases. The Aurora 19 industrial moisture analyzer is suitable for installation in safe areas and operates over a wide range of environmental conditions. The Aurora 19’s fast response immediately alerts when moisture concentrations are out of compliance; once corrected, gas can be quickly cleared for process normalization. Features include: Range • - Range 0 to 5000 ppm • - Lower Detection Point: 5 ppmv For CO2 applications: 50 ppmv • - Dew/Frost Point: -85.9° to 27.3°F (-65.5° to –2.6°C) frost point @ STP of 25°C, 14.696 psia • - Process Dew/Frost Point: Process or equivalent dew point/ frost point by calculation with process pressure signal (4-20 mA) or constant • - Absolute Humidity: 0.24 to 237 (3.8 to 3,803 mg/m3) lbs/MMSCF Accuracy • - Moisture reading (parts per million by volume): ±2% of reading or 4 ppmv • - For CO2 applications: ±3% of reading or 5 ppmv (Accuracy of other parameters derived from ppmv) • - Repeatability: ±0.2 ppmv or ±0.1%, whichever is greater; For CO2 applications: ±1.0 ppmv or ±0.5%, whichever is greater • - Calibration Certification: NIST or equivalent NMI traceable certification • - Calibration Options: Nitrogen, standard natural gas and 3 customizable calibration curves • - Response Time: Optical system <2 seconds • - Operating Sample Cell Pressure: 69 to 172 Kpa (10 to 25 psia) Flow Rate • - Sample Cell Flow Rate: 10 to 60 SLH (0.4 to 2 SCFH ); 30 SLH (1 SCFH) nominal • - By-Pass Fast Loop: 5 to 10X of flowrate through sample cell, available upon request

Catalogs

No catalogs are available for this product.

See all of Panametrics, a Baker Hughes business‘s catalogs

Exhibitions

Meet this supplier at the following exhibition(s):

Hyvolution 2025
Hyvolution 2025

28-30 Jan 2025 paris (France) Stand 4M36

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.