Desiccant compressed air dryer TWP series
externally heated

Desiccant compressed air dryer - TWP series - Parker Industrial Gas Filtration and Generation Di - externally heated
Desiccant compressed air dryer - TWP series - Parker Industrial Gas Filtration and Generation Di - externally heated
Desiccant compressed air dryer - TWP series - Parker Industrial Gas Filtration and Generation Di - externally heated - image - 2
Add to favorites
Compare this product
 

Characteristics

Technology
desiccant
Other characteristics
externally heated
Capacity

Max.: 8,000 ft³/min
(226.53 m³/min)

Min.: 200 ft³/min
(5.66 m³/min)

Working pressure

135 psi, 150 psi

Operating temperature

Max.: 120 °F
(48.9 °C)

Min.: 50 °F
(10 °C)

Ambient temperature

Max.: 120 °F
(48.9 °C)

Min.: 40 °F
(4.4 °C)

Weight

Max.: 12,002 lb
(5,444 kg)

Min.: 680 lb
(308.4 kg)

Dew point

-40 °F
(-40 °C)

Description

Compressed air is polluted with dirt particles, water, oil, oil vapor, and condensate. These contaminants result in high maintenance costs, premature wear, spoiled products and the failure of control systems. A Parker Airtek TWP Series Externally Heated Desiccant Air Dryer will effectively remove contaminants such as dirt, water, and oil. The traditional adsorption principle used in this design is simple, robust and flexible. Continuous drying is accomplished by the operation of two desiccant towers. Compressed air is dried through one tower while the other desiccant tower is being regenerated. The regeneration heating cycle of desiccant is accomplished using a dry air purge flow heated by an external electric heater. The regeneration cooling cycle is performed using the same flow of dry compressed air taken from the desiccant air dryer outlet to ensure continuous dewpoint performance. Features/Benefits • Delivered air quality is in accordance with ISO 8573.1: 2001, the international standard for compressed air quality. • Parker Airtek pre- and after compressed air filters - Standard • PowerLoc Energy Management System* - Standard • Low-wattage high incoloy sheathed heater for efficient regeneration • High-efficiency, quiet running regenerative (up to 3000 scfm) or centrifugal blowers (4000 scfm and larger) • Parker non-lubricated full-flow angle seat valves,