The CVS HT cell, made of steel, has been designed for the measurement of forces and works both in tension and compression. It has excellent linearity and accuracy and withstands overloads of over 300%. It has a watertight seal for use in severe environmental conditions, especially where there are high temperatures.
Technical Specifications
Rated load RL: 5, 10, 20, 30, 50, 100, 200, 300, 600, 1000 kN
Combined error: ±0.08 % RO
Repeatability: ±0.02 % RO
Creep (20 minutes): ±0,02 % RO
Safe overload: 150 % RL
Ultimate overload: > 300 % RL
Material: Stainless steel 17-4PH
Degree of protection: IP67
Deflection: 0.35 mm
Compensated Temperature: -10 ÷ +90 °C
Temperature range: -20 ÷ +120 °C
Temperature effect on zero balance: < ±0.005 % RO/°C
Temperature effect on output: < ±0.005 % RO/°C
Rated output RO: 2.0 mV/V ±0.1 %
Zero balance: 5000 MOhm
Input resistance: 700 ±20 Ohm
Output resistance: 700 ±5 Ohm
Recommended input: 2 ÷ 15 Vdc/ac