The off center load cell C2Z1 is easy to assemble and guarantees high performance in terms of precision and resistance, especially to humidity. For this reason, it is usually used in scales for commercial use. The off-center cell C2Z1 has an excellent quality-price ratio as it has an advantageous price compared to its features.
Technical Specifications
Rated load RL: 60, 120, 150, 300 Kg
Repeatability: ±0.02 % RO
Creep (20 minutes): ±0.025 % RO
Full scale non-Linearity: 0.02 % RO
Safe overload: 150 % RL
Ultimate overload: 250 % RL
Material: Alluminum
Compensated Temperature: -10 ÷ +50 °C
Temperature range: -10 ÷ +70°C
Temperature effect on zero balance: 0.028 % PN/°C
Temperature effect on output: 0.011 % on output/°C
Rated output RO: 1.9 mV/V ±0.1
Zero balance: ±5 % RO
Insulation resistance: <1000 Ohm
Input resistance: 400 ± 20 Ohm
Output resistance: 350 ±5 Ohm
Recommended input: 12 V
Maximum supply voltage: 20 V
Weight: 1 kg
Cable Lenght: 0,5 m
Hysteresis: 0.02 % RO