Thermocouple calibrator PIE 422Plus
temperaturecurrentHART

Thermocouple calibrator - PIE 422Plus - PIE - Pratical Instrument Electronics, Inc - temperature / current / HART
Thermocouple calibrator - PIE 422Plus - PIE - Pratical Instrument Electronics, Inc - temperature / current / HART
Thermocouple calibrator - PIE 422Plus - PIE - Pratical Instrument Electronics, Inc - temperature / current / HART - image - 2
Thermocouple calibrator - PIE 422Plus - PIE - Pratical Instrument Electronics, Inc - temperature / current / HART - image - 3
Thermocouple calibrator - PIE 422Plus - PIE - Pratical Instrument Electronics, Inc - temperature / current / HART - image - 4
Thermocouple calibrator - PIE 422Plus - PIE - Pratical Instrument Electronics, Inc - temperature / current / HART - image - 5
Thermocouple calibrator - PIE 422Plus - PIE - Pratical Instrument Electronics, Inc - temperature / current / HART - image - 6
Add to favorites
Compare this product
 

Characteristics

Physical quantity
temperature, current
Applications
for thermocouples
Options
HART
Temperature

Max.: 60 °C
(140 °F)

Min.: -25 °C
(-13 °F)

Noise level

50 dB, 120 dB

Voltage

60 V

Description

•Two Calibrators in One! Calibrate all your thermocouple instruments AND your milliamp loops with the PIE 422Plus. It has all the functions of a 14 type thermocouple calibrator and can source 0 to 24 milliamps or simulate a two wire transmitter like a milliamp calibrator. You may also perform stand alone calibrations of two wire transmitters by simultaneously supplying the thermocouple input signal while supplying the 24 volts to power up the transmitter and monitoring the milliamp output signal. Powers HART™ transmitters with built-in 250 ohm resistor simplifying hookups with HART communicators. •Troubleshoot loop problems Quickly diagnose ground fault and current leakage with the patented loop diagnostic technology (US Patent# 7,248,058) •Calibrate directly in temperature (°C & °F) Stop carrying around a millivolt source and thermocouple tables. The PIECAL 422Plus works with the thermocouples you use including types J, K, T, E, R, S, B, N, G, C, D, L (J-DIN), U (T-DIN) and P (Platinel II). Easily set any value quickly to within 0.1° with the adjustable “EZ-DIAL” plus store any three temperatures for instant recall with the EZ-CHECK™ switch. You may also calibrate from -13.000 to +80.000 mV. Connect your thermocouple and the PIE 422Plus measures the probe in degrees C or F. Secondary display shows the millivolt value corresponding to the thermocouple temperature. •Calibration Lab Accurate & Stable The internal cold junction thermistor is accurate to ±0.05°C and is traceable to NIST.

VIDEO

Catalogs