PSSu, electronic module, failsafe, supply voltage, infeed periphery supply 24 V DC 10 A, infeed C-rail 10 A, for railway applications.
General data
Approval - CE
UKCA
TÜV
Application range - Standard/Fail-safe
Technical data
Electrical data
Purpose of U2 - Periphery Supply
Supply voltage 2 (V) - 24
Type of supply voltage U2 - DC
Tolerance of U2 - -30 %/+25 %
Pot. isolation UINT1 to U2 - 3050 V
Environmental data
App. site standard1 railway - EN 50125-3
App. site to standard1 railway - Gleisbereich (1m - 3m)
App. site standard2 railway - EN 61373
App. site to standard2 railway - Kategorie 1, Klasse A + B
Climatic suitability to ... - EN 50125-1
EN 60068-2-2
EN 60068-2-1
EN 50155
EN 60068-2-14
EN 50125-3
Ambient temperature standard - EN 50155
Ambient temperature - -40
Standard 2 for ambient temp. - EN 50125-1
Ambient temp. to standard 2 - -40 ... +70 °C
Standard 3 for ambient temp. - EN 50125-3
Ambient temp. to standard 3 - -40 ... +70 °C
Perm. operating height ASL - 2000 m
EMC to standard ... - EN 61000-4-4
EN 61000-6-2
EN 61000-4-5
EN 61000-4-6
EN 61000-6-4
EN 61000-4-2
EN 61000-4-3
Vibration to standard ... - EN 50125-3
Broad band noise to - EN 61373
Standard1 b/band noise, rail - EN 61373
Freq. broadband noise, rail - 5 ... 150 Hz
Accel. broadband noise, rail - 0,79 g RMS
Acc. shock to standard1 - 2g
Acc. shock to standard2 - 5g
Clearance & creepage dist. to - EN 50124-1
Overvoltage category - OV2
Pollution degree clear.&creep. - PD2
Protection type standard - EN 60529
Protection type, mounting - IP51
Protection type, housing - IP20