The level transmitters of the type series FSA30 operate according to the float principle with magnetic transmission. The float is lifted by the rising liquid level in the tank and actuates the contacts of a reed contact / resistance chain in the sliding tube by the magnetic field of the permanent magnet located in the float.
The output signal is a voltage proportional to the level. Due to the electronics used, up to two switching points, an analogue signal (current or voltage) and IO-Link are available for data use.
Typical applications
The sensor is used wherever small to medium fill levels of even aggressive media are measured. The measuring length between 250 and 3000 mm allows flexible use in many containers.
The nature of the FSA30 level switch and transmitter makes it particularly suitable for use in hydraulic, lubrication and cooling systems.
Because of their on-site display, the FSA30 are also ideal for installation at process-relevant points for visual inspection.
up to 2 switch points
analogue output 4...20 mA or 0...10 V
IO-Link communication interface
rotatable 320° display & electrical connection
resolution: 8 or 12 mm
redundant measurement system, direct measurement
suitable for media of density > 0.6 g/cm³
applicable for foam formation