Magnetic circuit breaker AFB Arc-free
arc protectionDCswitching

Magnetic circuit breaker - AFB Arc-free - PLUTON - arc protection / DC / switching
Magnetic circuit breaker - AFB Arc-free - PLUTON - arc protection / DC / switching
Magnetic circuit breaker - AFB Arc-free - PLUTON - arc protection / DC / switching - image - 2
Magnetic circuit breaker - AFB Arc-free - PLUTON - arc protection / DC / switching - image - 3
Magnetic circuit breaker - AFB Arc-free - PLUTON - arc protection / DC / switching - image - 4
Add to favorites
Compare this product
 

Characteristics

Type
magnetic
Electrical characteristics
short-circuit, high-speed, switching, DC, arc protection
Operating mode
high-speed
Applications
distribution
Primary current

2,500 A, 4,000 A

VDC

1,000 V

Description

AFB® is an innovative ultra high-speed DC circuit breaker based on PLUTON experience and advanced technologies. AFB® is provided for application in tram, trolleybus, light rail and metro traction substations power distribution systems. Application of arc-free interruption concept in DC circuit breaker provides the following significant benefits in comparison with a circuit breaker with standard switching and arc interruption: safety and environmental friendliness. No damaging effect of arc and contaminating combustion products; AFB applies innovative DC interruption concept, leading to high wear resistance. It allows to minimize costs on components, and maintenance is not required for a long period; AFB® circuit breaker is developed and manufactured according to EN 50123-2/IEC 61992-2, EN 50123-3, IEC 60947-3 standards requirements; in contrast to standard contact circuit breaker, which requires additional work space for plasma ejection in its operation, AFB® circuit breaker applies principle of power circuit interruption in vacuum. As a result, AFB® circuit breaker requires half the size of work space in comparison with standard circuit breaker, and there is no need to meet special requirements to insulation gaps; secure low current interruption. Breaker contacts damage prevention. 50 000 switchings to maintenance (including short circuit current interruption); short contacts opening time (1 ms). High-speed power contacts opening and possibility of circuit breaker tripping before short-circuit current reaching by current rate of rise (di/dt); short circuit current limitation is < 25 kA with peak calculated value 100 kA.

VIDEO

Other PLUTON products

Innovative solutions for DC current switching

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.