ATEX calibratable meter / flow meter with turbine
Descriptive
Atex Pump marking: II 3 G IIC T4 U.
Technical data
Materials: aluminium body - polypropylene turbine
Orifices: 1" BSP M/F
Max. pressure: 20 bars
Digital meter: for low-viscosity fluids with a turbine-equipped measuring system
Charge loss < 0.03 bar (120 l/min with diesel)
Accuracy: ± 1% in the flow rate range
Repeatability: 0.2%
Temperature of use: from -10°C to +50°C
Measuring system: calibratable turbine
Specifications and advantages:
ATEX calibratable meter / flow meter with turbine
Characteristics
Fluid - Petrol, Diesel
Technology - Turbine
ATEX - Yes
Pump marking - II 3 G IIC T4 U
Materials - Aluminium
Mechanism - Polypropylene
Max flow rate - 7 to 120 l/mn
Orifice - 1" BSP M/F