Double-conversion UPS 9155
single-phaseAClead-acid

Double-conversion UPS - 9155  - Powerware - single-phase / AC / lead-acid
Double-conversion UPS - 9155  - Powerware - single-phase / AC / lead-acid
Double-conversion UPS - 9155  - Powerware - single-phase / AC / lead-acid - image - 2
Double-conversion UPS - 9155  - Powerware - single-phase / AC / lead-acid - image - 3
Double-conversion UPS - 9155  - Powerware - single-phase / AC / lead-acid - image - 4
Double-conversion UPS - 9155  - Powerware - single-phase / AC / lead-acid - image - 5
Double-conversion UPS - 9155  - Powerware - single-phase / AC / lead-acid - image - 6
Double-conversion UPS - 9155  - Powerware - single-phase / AC / lead-acid - image - 7
Double-conversion UPS - 9155  - Powerware - single-phase / AC / lead-acid - image - 8
Add to favorites
Compare this product
 

Characteristics

Type
double-conversion
Electrical characteristics
single-phase, AC
Type of energy storage
lead-acid
Other characteristics
with LCD display, sine wave, emergency, with power factor correction (PFC), maintenance-free
Applications
data center, power distribution
Configuration
tower
Certifications
IEC, ISO
Output power kVA

8 kVA, 10 kVA, 12 kVA, 15 kVA
(0.016315 hp, 10.876969 hp, 13.596212 hp, 20.394317 hp)

Input voltage

Min.: 200 V

Max.: 240 V

Output voltage

Min.: 100 V

Max.: 240 V

Power

13,500 W, 15,000 W

Description

The Eaton 9155 UPS (formerly the Powerware 9155 UPS) is a single-phase, double-conversion online UPS. Providing 5,500 watts per square foot with a 0.9 output power factor, the 9155 UPS helps get the most value out of your floor space and data center operating budget. This UPS offers endless opportunities to build out the backup power system you need with an optional maintenance bypass switch, network card and relay communications outputs, and Eaton’s patented HotSync technology that makes it easy to add redundancy or capacity. Reduces total cost of ownership • More real power in less space with 0.9 output power factor • Industry-leading power density with small footprint and more power capacity than comparable UPSs • Sleek tower design that includes internal batteries Maximizes flexibility • Power distribution module options • Split phase architecture • Enables paralleling of up to four 9155 UPSs for additional capacity and redundancy Maximizes availability and reliability • Extended battery runtime options • Optional bypass to service UPS without disturbing the load • Connectivity and software options for remote monitoring and management Innovative three-stage battery charging system

Other Powerware products

Backup power, UPS, surge & IT power distribution