video corpo

Cabinet power distribution unit PDU
for data centersthree-phase

Cabinet power distribution unit - PDU  - Powerware - for data centers / three-phase
Cabinet power distribution unit - PDU  - Powerware - for data centers / three-phase
Cabinet power distribution unit - PDU  - Powerware - for data centers / three-phase - image - 2
Cabinet power distribution unit - PDU  - Powerware - for data centers / three-phase - image - 3
Cabinet power distribution unit - PDU  - Powerware - for data centers / three-phase - image - 4
Cabinet power distribution unit - PDU  - Powerware - for data centers / three-phase - image - 5
Cabinet power distribution unit - PDU  - Powerware - for data centers / three-phase - image - 6
Cabinet power distribution unit - PDU  - Powerware - for data centers / three-phase - image - 7
Cabinet power distribution unit - PDU  - Powerware - for data centers / three-phase - image - 8
Cabinet power distribution unit - PDU  - Powerware - for data centers / three-phase - image - 9
Add to favorites
Compare this product
 

Characteristics

Type
cabinet
Options
for data centers, three-phase
Power

Min.: 50,000 W

Max.: 500,000 W

Current

225 A, 400 A

Output voltage

208 V

Description

Eaton cabinet PDU plays an important role in any power management system. Designed to work on both non-raised and raised floors in a data center, with scalable architecture and front access only design, this 3-phase PDU provides unparalleled ease of use. By incorporating Eaton's Energy Management System (EMS) upgrade kit to optimize utilization and availability, this cabinet PDU provides comprehensive monitoring and alarming down to the branch circuit level. ELECTRICAL Input: 208/380/400/415/480/600V, 3 phase (single and dual input) Frequency: 60 Hz DISTRIBUTION Main cabinet (front/rear access PDU only): 2 panelboards and/or subfeeds Sidecar: 2 panelboards per cabinet Up to 252 pole positions Factory-installed breakers Electrical characteristics INPUT RATINGS 208/380/400/415/480/600V - 3 phase 3 wire + ground (single and dual input) Dual input: basic or premium OUTPUT RATINGS 208V - 3 phase, 4 wire + ground FREQUENCY 60 Hz TRANSFORMER TYPE Copper/double shielding/class R (220°C) insulation TRANSFORMER CHARACTERISTICS 150°C temp rise/K13 (standard) and K20 (optional) Complies with DoE 2016 efficiency standards TP-1 efficient transformers available for non-US customers TRANSFORMER COMPENSATION TAPS (4) 2-1/2% FCBN/(2) 2-1/2% FCAN NEUTRAL RATING 200%