Features
•ZVS Phase-Shift Full-bridge 2,5kW transformer
•Work with ZVS inductor 14µH / 14Apk
•Recommended output inductor 1µH / 180Adc
•Switching frequency 100kHz
•UL94 and RoHS materials (F/155°C)
•Design based on AEC-Q200
•Weight : approx 350grams
Application
•Automotive HV/LV DCDC onboard converters
Operation
•Vin = 376-820Vdc / Vout = 14Vdc
•Operating temperature -40/+125°C with cooling