- Partially visible flame
- Wide range of flow rates
- Insulated combustion chamber
EMR ADV flares are the most suitable solution in installations where combustion temperature and flame visibility are not subject to any regulation but it is required that the flame is partially hidden and contained inside a combustion chamber.
The multi-nozzle burner and the particular design, size and features of the combustion chamber allow the burning of biogas at a higher flow than in open flares.
Product features
Semi-enclosed flare
Stainless steel frame with base plates for anchoring to concrete slab
Combustion chamber fitted with fiberceramic insulation lining
High voltage electrode-type ignition device and UV sensor for continuous flame detection
Fully automatic operation