video corpo

Coriolis flow meter RHM 60
massfor waterDN100 - 4"

Coriolis flow meter - RHM 60 - Rheonik Messtechnik GmbH - mass / for water / DN100 - 4"
Coriolis flow meter - RHM 60 - Rheonik Messtechnik GmbH - mass / for water / DN100 - 4"
Coriolis flow meter - RHM 60 - Rheonik Messtechnik GmbH - mass / for water / DN100 - 4" - image - 2
Coriolis flow meter - RHM 60 - Rheonik Messtechnik GmbH - mass / for water / DN100 - 4" - image - 3
Add to favorites
Compare this product
 

Characteristics

Technology
Coriolis
Type
mass
Fluid
for water
Pipe diameter
DN100 - 4", DN125 - 5", DN150 - 6"
Installation
flange
Material
stainless steel
Protection level
rugged, ATEX, IP65, IP66, NEMA 4X
Mass flow rate

Max.: 3,000 kg/min
(6,613.87 lb/min)

Min.: 30 kg/min
(66.14 lb/min)

Process temperature

Max.: 490 °C
(914 °F)

Min.: -196 °C
(-321 °F)

Process pressure

Max.: 430 bar
(6,236.62 psi)

Min.: 0 bar
(0 psi)

Precision

0.1 %

Repeatibility

0.05 %, 0.1 %

Description

The RHM 60 is a robust sensor designed for 4″ line sizes. The availablity of a variety of wetted materials and wide pressure/temperature ratings allow use in applications throughout all industries. Materials: SS 316L / SS 316Ti, Super Duplex – 1.4410, Alloy C22 – 2.4602 Process Connection: 4" up to 4" General Specifications Operating Temperature Fluid temperature range options cover applications from -196°C to +350°C (-320°F to +662°F). For integral transmitter versions please refer to transmitter datasheet Electrical Connection Sensor w/o Integral Transmitter M20 x 1.5 standard cable entry for JM, SM terminal box versions Optional entries available : ½” NPT or M25 x 1.5 (only for SM) or ¾” NPT (only for SM) Max. cable length to remote RHE transmitter 100 m / 328 ft Process Connections Nearly any – the Rheonik AnyPipeFit Commitment. Consult factory for types/sizes not listed Pressure Rating Compliance Europe – PED: Module A2, Module B3.1+C2 Canada – CRN: Canadian Registration Number Certifications and Approvals North American Approvals Class I, Div. 1, 2, Gr. A,B,C,D, Zone 0, 1, 2 MID custody transfer approval (OIML R117) American Bureau of Shipping (ABS) Product Type Approval for use on marine vessels Testing and Inspection All sensors are hydro tested, calibrated and supplied with a traceable calibration certificate. Customized calibration and testing services are available
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.