Double-conversion UPS Sentryum
single-phasethree-phaseVRLA

Double-conversion UPS - Sentryum  - RIELLO UPS - single-phase / three-phase / VRLA
Double-conversion UPS - Sentryum  - RIELLO UPS - single-phase / three-phase / VRLA
Add to favorites
Compare this product

Characteristics

Type
double-conversion
Electrical characteristics
single-phase, three-phase
Type of energy storage
VRLA, AGM, Li-ion, Ni-Cd
Other characteristics
with LCD display, Eco mode, modular
Applications
industrial
Configuration
rack-mount
Certifications
IEC
Output power kVA

Min.: 20 kVA
(27.192423 hp)

Max.: 160 kVA
(217.539385 hp)

Input voltage

Min.: 220 V

Max.: 415 V

Output voltage

Min.: 220 V

Max.: 415 V

Power

Min.: 20,000 W

Max.: 160,000 W

Description

The Sentryum Rack range was specially developed to ensure power continuity in all sectors deemed critical due to the specific environmental conditions or industrial processes requiring protection. It is a true ON LINE double-conversion UPS, available in a 20 kVA/kW standalone version and in modular versions from 20 to 160 kVA/kW. The Sentryum Rack is available in both single-phase and three-phase output configurations. It accepts both single-phase and three-phase inputs with no need for special setups or operator intervention. The voltage arrangement could change during operation without any reset or manual operation, therefore the UPS auto-detects the input voltage and behave accordingly. High efficiency, power availability, and reliability This Series is derived from the Sentryum and essentially inherits its main technologies and peculiarities: Full power rating available up to 40 °C (kVA=kW unity pf) and up to 96.3% VFI efficiency; Zero impact source, thanks to a very low input THDi <3%, input pf 0.99, power walk-in function, power walk-in start delay function; Up to 20 Amps battery recharging current and wide battery block range (the standard 20+20 battery blocks @ 12V with Neutral central point can be adjusted from 15+15 to 22+22); Three-level IGBT inverter, extremely low output THDv; Up to 270% inverter current for 200 msec. and 150% for 300 msec., which enables the system to deal with sudden peak loads (without static bypass intervention) and provide the short circuit current if required during operation on battery; “Cold start” function for starting the UPS from the battery.

Catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.