Characteristics

Type
on-line, double-conversion
Electrical characteristics
three-phase
Type of energy storage
VRLA, AGM, Li-ion, Ni-Cd
Other characteristics
compact, with built-in battery, high-performance
Applications
industrial, data center, medical
Configuration
tower
Certifications
IEC
Output power kVA

Max.: 600 kVA
(815.772693 hp)

Min.: 100 kVA
(135.962116 hp)

Input voltage

380 V, 400 V, 415 V

Output voltage

380 V, 400 V, 415 V

Power

Max.: 800,000 W

Min.: 90,000 W

Description

The Master HP series from 100 to 600 kVA is the Riello UPS solution for installations requiring high energy efficiency and maximum power availability. Master HP Series provides maximum protection and power quality for data centres and industrial loads. The UPS has an IGBT-based rectifier, DSP (Digital Signal Processor) technology and provides true-line, double conversion power protection, (VFI SS 11 - Voltage and Frequency Independent in accordance with IEC EN 62040-3). The Master HP serie features the added advantages of the Zero Impact Source formula offered by an IGBTbased rectifier assembly. This eliminates problems connected with installation in networks with limited power capacity, where the UPS is supplied by a generator set or anywhere there are compatibility problems with loads generate current harmonics. Master HP series UPS have zero impact on the power supply source, whether it is a mains grid or generator set: input current distortion <3%; input power factor 0.99; power walk-in function that ensures progressive rectifier start up; start up delay function, to restart the rectifiers when mains power is restored if there are several UPS in the system. Battery Care System: maximum battery care Master HP series UPS include a range of features designed to prolong battery life and reduce their usage such as different recharging methods, deep discharge protection, current limitation and voltage compensation according with battery room temperature.