The RIF150 measurement principle allows measurements to be performed in both directions of flow, and enables accurate measurements regardless of density, temperature, and viscosity.
The output signal can be 4...20 mA, pulses, and RS485 Modbus. The body is made of AISI 316L with an internal coating of Peek. The RIF150 is ideal for measuring conductive liquids such as cooling water or hot water, beer, wine, milk, water-based soaps, acid solutions compatible with contact materials. The measuring range is 0.2...100 l/min. depending on the diameter.
The process connection can be 3/8" NPT or 1/2" NPT. The maximum temperature is 60°C and the maximum pressure is 16 bar. The RIF150 is equipped with a display for immediate monitoring and simultaneous display of flow and temperature. Compact construction ideal for use in tight spaces, high shock and vibration resistance.
PRODUCT FEATURES
Detection type - Continuous measurement
Measurable media - Leachate, Beverages, Chlorine Water, Milk, Potash, Rainwater (acidic), Water., Aggressive Liquids, Wine, Liquids with conductivity> 20µS/cm
Documentation included - English instructions manual, Italian instructions manual, Test report
Explosion protection - Safe zone
Integrated temperature sensor - None
Properties of the fluid - Viscous / Sticky, Aggressive, Abrasive, Foamy, Presence of suspended solids
Zero point calibration - Yes
Minimum conductivity of the fluid - 20 µS/cm
DETAILS OF THE SIGNAL INPUTS AND OUTPUTS
Signal Output Type - Digital and Analog
Analog output functions - Volumetric flow
Frequency output functions - Volumetric Flow, Mass Flow
Maximum error of the analog output - 0,1% ± 10 μA
Digital output type - Relay - pulse